====== DMX512 controlled LED light fixture project ====== This light will be used at the Oakland Scottish Rite auditorium. Currently the auditorium is illuminated by the column lights using HPL575 halogen light bulb that are 575W each. Each light produces 575W * 24lm/W((efficacy for quartz halogen bulb)) = 13800lm each. There are 24 column lights producing total of **331200 lm**. This is a minimum lighting which is not adequate for the auditorium size. The power consumption of the lights is 575W * 24 = **13.8KW**. There are also the original lights mounted in a circle around the perimeter of the dome. There is x number of white 100W light bulbs, g number of green light bulbs and r number of red light bulbs. The number and light output is to be determined. ===== Design specifications ===== The goal is to replace the existing light bulbs and fixtures around the perimeter of the auditorium with LED light fixtures. The replacement should pay for itself in 5 years by saving electricity. The 5 year goal is to be able to finance the upgrade by 0% financing available from PG&E available for such projects. *The light output should produce xx lumens at the floor of the auditorium *Total power consumption should be << 50% of the current power consumption *The light should produce white spectrum with CRI better than 75 *The light output should be controllable on granular level with individual control for red, green, blue and white *The ratio of output light intensity between white and RGB is to be determined *The control will be done by DMX, use DMX over Ethernet for the uplink from control station to the ceiling level *Input power is 110V *Design for reliability Q: Should design for the new RDM protocol instead? ===== Hardware ===== ==== LED selection ==== -good performance/price -> high ratio of lm/$ **RGB LED** ^ LED PN ^ Datasheet ^ Max op current ^ Nominal lm((total summing all three colors)) ^ Price@qty 100 ^ 100W eq((number of LEDs required to replace one 100W incandescent light bulb 1600lm or 127cd)) ^ price/100W eq ^ ^ LRTBC9TP-CWD5-1+D5E7-25+A | [[http://catalog.osram-os.com/catalogue/catalogue.do;jsessionid=E7482437329485DE8E76AF3A5C09D2A5?act=downloadFile&favOid=02000000000018a0000300b6|Data]] | 250mA | 62 | 3.41 | 25.80 | 88 | ^ MCE4CT-A2-0000-00A5AAAA1((Four colors LED)) | [[http://www.cree.com/products/pdf/XLampMC-E.pdf|Data]] | 700mA | 350 | 17.7 | 4.58 | 81.18 | ^ LTRBGFSF-ABCB-QKYO-Z | [[http://catalog.osram-os.com/catalogue/catalogue.do;jsessionid=E7482437329485DE8E76AF3A5C09D2A5?act=downloadFile&favOid=0200000400012409000100b6|Data]] | 50 | 50 | 1.16 | 27.8 | 32 | ^ CLV1A-FKB-CJ1M1F1BB7R4S3 | [[http://www.cree.com/products/pdf/LEDlamps/CLV1A-FKB(874).pdf|Data]] | 25 | 22 | 0.52 | 72 | 37 | ^ GM5WA06260A | [[http://media.digikey.com/pdf/Data%20Sheets/Sharp%20PDFs/GM5WA06260A.pdf|Data]] | 35 | 22.4 | 3.05 | 71 | 217 | ^ AAAF5060QBDZGSEES | [[http://www.kingbrightusa.com/images/catalog/SPEC/AAAF5060QBDZGSEES.pdf|Data]] | 30(50) | 33 | 1.32 | 48 | 63 | ^ ^ ^ ^ ^ ^ ^ ^ ^ CREE XP-C 3x LED | [[http://www.cree.com/products/pdf/XLampXP-C.pdf|Data]] | 350 | 40+65+27(132) | 2.53+3.88+2.27(8.68) | 12 | 105 | ^ XPCRED-L1-R250-00201 | [[http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=XPCRED-L1-R250-00201CT-ND|Data]] | 350 | 40 | 2.53 | 12 | 105 | ^ XPCGRN-L1-R250-00801 | [[http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=XPCGRN-L1-R250-00801CT-ND|Data]] | 350 | 65 | 3.88 | 12 | 105 | ^ XPCBLU-L1-0000-00W01 | [[http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=XPCBLU-L1-0000-00W01CT-ND|Data]] | 350 | 27 | 2.27 | 12 | 105 | **White LED ** ^ LED PN ^ Data ^ Max op current ^ Nominal lm ^ Max lm ^ lm/W ^ Price@volQty ^ 100W eq((number of LEDs required to replace one 100W incandescent light bulb 1600lm or 127cd)) ^ price/100W eq ^ Note ^ ^ MLBAWT-A1-0000-000WE7 | [[http://www.cree.com/products/pdf/XLampML-B.pdf|Data]] | 175 | 18@80 | 25lm@120mA,3.5V | 59 | 0.55 | 64 | 35 | Used in Demo unit | ^ MX6SWT-A1-0000-000CE7 | [[http://www.cree.com/products/pdf/XLampMX-6s.pdf|Data]] | 175 | 100@60 | 200lm@145@22.8(!) | 60.4 | 1.38 | 7.5 | 10.0 | | ^ STW8Q14BE-T0T5-GA | [[http://media.digikey.com/pdf/Data%20Sheets/Seoul%20Semiconductor/STW8Q14BE_Spec.pdf|Data]] | 150 | 30.5@100 | 46lm@150@4.7V | 64 | 0.266 | 36 | 9.57 | | ^ XPEWHT-L1-0000-00BE7 | [[http://www.cree.com/products/pdf/XLampXP-E.pdf|Data]] | 1000 | 94@350 | 225lm@1000@3.5V | 64 | 2.13 | 7 | 15.14 | Used by Esika | ^ XBDAWT-00-0000-00000LBE7 | [[http://www.cree.com/products/pdf/XLampXB-D.pdf|Data]] | 500 | 87@350 | 135 lm@500@3.0V | 90 | 0.9 | 11.9 | 10.6 | [[http://www.cree.com/products/xlamp_xbd.asp|New from Cree]] | ==== Power supply ==== The system will require reliable power supply source. Requrements: -UL certified power supply -Well known brand -Sufficient power output ~400-500W -Output voltage 48 -80V -Fanless for relable operation *[[http://www.newark.com/tdk-lambda/dpp480-48-1/power-supply-switch-mode-48v/dp/18M4560|TDK 480W 48V PS]] 200$ each, rail mountable === Medium 200-300W power supply option 1x PS for two lights === *[[http://www.jameco.com/Jameco/Products/ProdDS/2102932.pdf| HRPG-300-36 ]] 300W, 36V with PFC and active surge current limiting === Small power supply option for each light === *[[http://www.jameco.com/Jameco/Products/ProdDS/2147145.pdf| HLP-80H-30 ]] POWER SUPPLY,SWITCHING,OPEN FRAME,80 WATT,30VDC@2.7A,90-305Vin,UL/CUL/TUV/CE/PFC $43 each === LED driver === * [[http://cds.linear.com/docs/Datasheet/3476fb.pdf| 4ch LED driver LT3476, 33V max,1A $5.60 each ]] * [[http://www.diodes.com/datasheets/ZXLD1356.pdf| 1ch LED driver ZXLD1356]]48V,0.55A max, 4x$1.40 = 5.60, ZXLD1366 is 1A version ===== Thermally clad PCB ===== Metal core PCB and standard FR-4 are commonly used circuit board materials in conjunction with Power LEDs. Bergquist’s Thermal Clad dielectric is a thin, thermally conductive layer bonded to an aluminum or copper substrate for heat dissipation. The key to Thermal Clad’s superior performance lies in its dielectric layer.This layer offers electrical isolation with high thermal conductivity and bonds the base metal and circuit foil together. Other manufacturers use standard prepreg as the dielectric layer, but prepreg doesn’t provide the high thermal conductivity and resulting thermal performance required to help assure the lowest possible operating temperatures and brightest light output for high-intensity LEDs.Thermal Clad circuit board materials are available from The Bergquist Company in four different thermal conductivities, High Power Lighting (HPL), High Temperature (HT), Low Modulus (LM) and Multi-Purpose (MP). * [[http://www.bergquistcompany.com/pdfs/T-Clad%20Optimal%20Design%20White%20Paper.pdf| Guidelines]] {{:t-cladoptimaldesignwhitepaper.pdf|Cached version}} ===== Firmware ===== ====== Blog ====== === 5-1-2011 Started Research === ====== Links and other info ====== ===== Light sources efficiency and efficacy ===== **1 cd = 13 lm** ^Type^Overall luminous efficiency^Overall luminous efficacy (lm/W) ^ Output lm ^ Output cd ^ |40 W tungsten incandescent|1.9%|12.6| | | |60 W tungsten incandescent|2.1%|14.5| 800 | 64 | |100 W tungsten incandescent|2.6%|17.5| 1600 | 127 | |glass halogen|2.3%|16| | | |quartz halogen|3.5%|24| | | |high-temperature incandescent|5.1%|35| | | |ideal [[black-body]] radiator at 4000K (or a [[Stellar classification|class]] K star like [[Arcturus]])|7.0%|47.5| | | |ideal black-body radiator at 7000 K (or a [[Stellar classification|class]] F star like [[Procyon]])|14%|95| | | |ideal monochromatic 555 nm (green) source|100%|683| | | [[http://en.wikipedia.org/wiki/Incandescent_light_bulb|Source]] ===== Links ===== === DMX512 === *[[http://www.usitt.org/DMX512FAQ.aspx#a13|DMX512 FAQ]] *[[http://www.microchip.com/stellent/idcplg?IdcService=SS_GET_PAGE&nodeId=1406&dDocName=en549342|LED controller with DMX control from Microchip]] *[[http://ww1.microchip.com/downloads/en/AppNotes/01076A.pdf|Microchip AN1076, DMX controlled dimmer]] == DMX 512 specifications == * DMX uses 256Kbit communication over RS485 bus. No error checking, no reliable delivery. * Addressing is manual, by switches or in software, no auto addressing. * DMX512 packe takes 1204 usec to 1 s. * Maximum is 32 devices per bus + master. There can be a splitter that will allow multiple chains of 32 devices connected to the master. * Max lenght is 1200m. * Nominal imepdance 120 Ohm, bus should be properly terminated. == XLR 5 pin connector == - Signal common - Data 1- (Primary) - Data 1+ (Primary) - Data 2- (Optional) - Data 2+ (Optional) === DMX Over Ethernet === *[[http://www.enttec.com/index.php?main_menu=Products&pn=70305&show=description&name=ode|Enttec DMX over Ethernet]] === RDM === * [[http://en.wikipedia.org/wiki/RDM_%28lighting%29|RDM at Wikipedia]] * [[http://www.rdmprotocol.org/|RDM forum]] * [[http://www.enttec.com/index.php?main_menu=Products&pn=70530&show=description&name=rdmusbpro|ENTTEC RDM USB Pro Adapter]] Namespace: dmx_led: